Skip to main content
Version: 2.2.0

STRDELVALUES - Delete indicator values

This import template allows:

  • Deleting indicator values.

To perform this action, the standard documented below must be followed.

Deletion​

ColumnRequiredTypePrecisionDescription
OIDINTERFACEXTEXT32Sequential code - Identifies an item to be imported into SoftExpert Suite.
FGIMPORTXNUMERIC2Import status:
1 - New;
2 - In progress;
3 - Finished;
4 - Error.
CDISOSYSTEMXNUMERIC10Code of the system in which the integration will be performed:
138 - Code of the SoftExpert Performance component.
FGOPTIONXNUMERIC2Code of the operation to be performed:
15 - Delete indicator values.
NMFIELD01XTEXT50Scorecard indicator ID #
NMFIELD02XTEXT50ID of the user with import permission in the scorecard or target and/or measurement permission in the indicator.
NMFIELD03X¹TEXT2For daily indicators, the target/measurement day must be entered, from 1 to 31.
For weekly indicators, the number of the week of the month for target/measurement must be entered, from 1 to 5.
For biweekly indicators, the number of the fortnight of the month for target/measurement must be entered, 1 or 2.
For indicators with other frequencies, it must remain empty.
NMFIELD04X²TEXT2For daily, weekly, biweekly or monthly indicators, the number of the month must be entered, from 1 to 12.
For bimonthly indicators, the number of the bimester for target/measurement must be entered, from 1 to 6.
For quarterly indicators, the number of the quarter for target/measurement must be entered, from 1 to 4.
For four-month-period indicators, the number of the four-month-period for target/measurement must be entered, from 1 to 3.
For biannual indicators, the number of the semester for target/measurement must be entered, 1 or 2.
For yearly indicators, it must remain empty.
NMFIELD05XTEXT4Target/measurement year with 4 digits.
E.g.: 2020.
NMFIELD06X³TEXT50Period ID #. Only for indicators with "Based on event" frequency.
NMFIELD07NUMERIC1Delete target value?
1 - Yes;
2 - No (default).
NMFIELD08NUMERIC1Delete measurement value?
1 - Yes;
2 - No (default).
NMFIELD09NUMERIC1Delete accumulated target value?
1 - Yes;
2 - No (default).
NMFIELD10NUMERIC1Delete accumulated measurement value?
1 - Yes;
2 - No (default).
NMFIELD11NUMERIC1Delete additional field 1 value?
1 - Yes;
2 - No (default).
NMFIELD12NUMERIC1Delete additional field 2 value?
1 - Yes;
2 - No (default).
NMFIELD13NUMERIC1Delete additional field 3 value?
1 - Yes;
2 - No (default).
NMFIELD14NUMERIC1Delete accumulated additional field 1 value?
1 - Yes;
2 - No (default).
NMFIELD15NUMERIC1Delete accumulated additional field 2 value?
1 - Yes;
2 - No (default).
NMFIELD16NUMERIC1Delete accumulated additional field 3 value?
1 - Yes;
2 - No (default).
info

Note:

  • X¹ - Field required if the indicator entered has "Daily", "Weekly", or "Biweekly" frequency.
  • X² - Field required if the indicator entered has any frequency other than "Yearly".
  • X³ - Field required if the indicator entered has "Based on event" frequency.